    XG PON N1 OLT XFP Transceiver

    XG PON N1 OLT XFP Transceiver

    The HG Genuine PLGX1-01A transceiver consists 1577nm DFB EML laser, 1270nm APD photodiode WDM filter and Preamplifier in a high-integrated optical sub-assembly for 2.5G upstream and 10G downstream GPON applications up to 20km. The optical interface is SC
    在线订购
    订购信息提交成功!稍后客服人员会第一时间与您联系!
                联系电话:0712-2650028   传 真:0712-2584937
    产品模块: XG PON N1 OLT XFP Transceiver
    订购信息:
    验证码:
    在线留言
    在线留言提交成功!稍后客服人员会第一时间与您联系!
                联系电话:0712-2650028   传 真:0712-2584937
    类 别: 电子邮箱:
    电 话: QQ:
    *标题:
    *留言内容:
    *验证码:
    字体显示:

    Description

    The HG Genuine PLGX1-01A transceiver consists 1577nm DFB EML laser, 1270nm APD photodiode WDM filter and Preamplifier in a high-integrated optical sub-assembly for 2.5G upstream and 10G downstream GPON applications up to 20km. The optical interface is SC/UPC receptacle. It adopts XFP Package. Power supply is single +3.3 Voltage.

     

    Features  

    XFP Package.

    Single Power Supply +3.3 Voltage.

    Single Fiber Bi-Directional SC/UPC receptacle.

    1577nm continuous-mode 10.3125Gb/s DFB EML transmitter

    1270nm burst-mode 2.5Gb/s APD receiver

    SFP electrical interface

    2-wire interface for integrated Digital Diagnostic monitoring

    Operating temperature range: 0 °C ~+70 °C


    Applications

    10 Gigabit PON OLT application

     

    Compliance

    Compliant with INF-8077i

    Compliant with IEEE 802.3av

    Compliant with IEC60825 Class 1

    RoHS compliance

     

    Specification

     

    Absolute Maximum Ratings

    Parameter

    Symbol

    Min

    Typical

    Max

    Unit

    Notes

    Storage Temperature

    TSTG

    -40


    85

    ºC


    Operating Relative Humidity


    5


    95

    %


    Supply Voltage

    VCC

    -0.5


    4

    V


    Ambient temperature

    Ta

    -25

    -

    +75


     

    Recommended Operating Conditions

    Parameter

    Symbol

    Min

    Typical

    Max

    Unit

    Notes

    Case Operation Temperature

    Ta

    0


    70

    ºC


     Supply Voltage  

    VCC

    3.135

    3.3

    3.465

    V


     Module Power Dissipation  

    P



    2.5

    W


     

    Tested under recommended operating conditions, unless otherwise noted

    Transmitter OperatingCharacteristic-Optical,Electrical

    Parameter

    Symbol

    Min

    Typical

    Max

    Units

    Notes

     Data Rate  

    BR


    9.953


    Gb/s


    Differential Input Voltage

    Vin p-p

    120

    -

    820

    mV


     Output Optical Power

    PO

    2.5

    -

    6

    dBm

    BOL

    2

    -

    6

    dBm

    EOL

     Extinction Ratio

    ER

    8.2

    -


    dB


    Center Wavelength Range

    λc

    1575

    1577

    1580

    nm


    Spectrum Width(-20dB)

    Δλ

    -

    -

    1

    nm

    DFB EML

    Side Mode Suppression Ratio

    SMSR

    30

    -

    -

    dB


    Transmitter Dispersion Penalty

    Tdp

    -

    -

    1

    dB


    Total jitter

    TJ

    -

    -

    0.3

    UI


    Output Optical Eye

    Complies with IEEE802.3av eye masks when filtered

    Tx_Disable Voltage

    VOH

    2.0

    -

    Vcc

    V

    LVTTL

    VOL

    0

    -

    0.8

    V

    LVTTL

    Laser turn on Time

    Ton



    2

    ms


    Laser turn off Time

    Toff



    10

    us


     

    Receiver Operating Characteristic-Optical,Electrical 

    Parameter

    Symbol

    Min

    Typical

    Max

    Units

    Notes

    Differential Output Voltage

    Vout p-p

    340


    850

    mV

    50Ω load to Vcc-2V

    Receiver Optical Wavelength

    λIN

    1260

    1270

    1280

    nm


    Receiver Sensitivity

    Sen



    -30.5

    dBm

    BOL,Note1



    -29.5

    dBm

    EOL,Note1

    Overload Input Power

    So

    -7



    dBm


    SD of Signal Voltage

    Nomal

    2.4


    Vcc

    V

    LVTTL

    Fault

    0


    0.4

    V

    LVTTL

    SD Asserted

    SD_A



    -28.5

    dBm


    SD De-asserted

    SD_D

    -39



    dBm


    SD Hysteresis

    PD- PA

    0.5


    5

    dB


    Optical Return Loss

    -



    -20

    dB


    SD_A Settling Time



    50


    ns


    SD_D Settling Time



    12.8


    ns


    Reciever Dynamic range


    15



    dB


    Reset Effective Level

    HL



    High



    Reset Width


    64



    Bit


    Data receiver Time




    64

    Bit


     Notes:

    [1]Measured with PRBS 2^23-1 test pattern @2.5Gbps with Tx on, ER=8.2dB, BER=10^-4.

     

    Reliability Test Definitions and Distributions

    Group

    Test

    Reference

    Condition

    SS[1]

    C[2]

    Mechanical Integrity

    Mechanical shock

    MIL-STD-883

    Method 2002.3

    5 times/axis,

    1500G, 0.5ms

    11

    0

    Vibration

    MIL-STD-883

    Method 2007.2

    20G, 20~2000Hz,

    4min/cys,4cys/axis

    11

    0

    Thermal Shock

    MIL-STD-883 Method 1011

    T=100c

    00C-1000C

    11

    0

    Endurance

    Accelerated Aging

    GR-468-CORE

    85, 2000 hrs

    11

    -

    High temperature Storage

    GR-468-CORE

    85, 2000 hrs

    11

    0

    Low temperature Storage

    GR-468-CORE

    -40, 72 hrs

    11

    0

    Temperature Cycles

    MIL-STD-883

    Method 1010.7 GR-468-CORE

    -40~85

    500 cycles

    11

    0

    Damp Heat

    MIL-STD-202

    Method 103

    GR-468-CORE

    85 ,85%RH

    1000 hrs

    11

    0

    Cyclic moisture resistance

    MIL-STD-883

    Method 1004.7 GR-468-CORE

    20 cycles

    11

    0

    Special Test

    ESD threshold

    MIL-STD-883E

    Method 3015.7

    2000V HBM

    6

    0

    Note:

    [1] SS: Sample Size;

    [2] C: Maximum number of failure allowed in the test.


    Digital Diagnostic Monitoring Information

    Parameter

    Range

    Actual Value

    Calibration Option

    Note

    Transceiver Temperature

    -40~85

    ±3℃

    Internal calibration

    Recommended

    Operating Conditions

    Power Supply Voltage

    3.0-3.6V

    ±3%

    Internal calibration

    Recommended

    Operating Conditions

    Tx Bias Current

    0~262mA

    ±10%

    Internal calibration

    Recommended

    Operating Conditions

    Tx BM Optical Power

    2~6dBm

    ±3dB

    Internal calibration

    Recommended

    Operating Conditions

    Rx Optical Power

    -30.5~-7dBm

    ±3dB

    Internal calibration

    Recommended

    Operating Conditions


    Pin-out Description

    图片1.jpg


    Pin Assignment 

    Pin

    Name

    Description

    1

    GND

    Module Ground

    2

    Not Implemented


    3

    Not Implemented





    4

    Not Implemented





    5

    TX_DIS

    transmit disable; when high, transmitter output is turned OFF, Internal pull up

    6

    VCC5

    5V power supply

    7

    GND

    Module Ground

    8

    VCC3

    3.3V power supply

    9

    VCC3

    3.3V power supply

    10

    SCL

    2-Wire Serial Interface Clock

    11

    SDA

    2-Wire Serial Interface Data Line

    12

    Mod _ABS

    Indicates Module is not present; Host shall put-up this pin and grounded in the module. When "High" the XFP module is absent from host board

    13

    RX_RST

    Burst Receiver Reset

    14

    RX_SD

    Burst Packet Detect, Higher level indicates that burst packet is detected by the receiver

    15

    GND

    Module Ground

    16

    GND

    Module Ground

    17

    RD-

    Receive Burst Mode Inverted Data Output; DC coupled inside the module

    18

    RD+

    Receive Burst Mode Non-Inverted Data Output; DC coupled inside the module

     

    Figure Dimensions

     图片2.jpg


    Digital Diagnostic Memory Map

    图片3.jpg

    EEPROM Information

    A0H

    Addr.

    Field Size

    Name of Field

    Hex

    Description

    (Bytes)

    0

    1

    Identifier

    0x06

    XFP

    1

    1

    Signal Conditioner Control

    0x00

    Data Rate:9.52Gb/s

    Normal Asynchronous REFCLK mode

    2-3

    2

    Temperature High Alarm

    80

    MSB at low address

    4-5

    2

    Temperature Low Alarm

    -10

    MSB at low address

    6-7

    2

    Temperature High Warning

    75

    MSB at low address

    8-9

    2

    Temperature Low Warning

    -5

    MSB at low address

    10-11

    2

    Vcc High Alarm

    3.6V

    MSB at low address

    12-13

    2

    Vcc Low Alarm

    3.0V

    MSB at low address

    14-15

    2

    Vcc High Warning

    3.5V

    MSB at low address

    16-17

    2

    Vcc Low Warning

    3.1V

    MSB at low address

    18-19

    2

    10G Bias High Alarm

    XX

    MSB at low address

    20-21

    2

    10G Bias Low Alarm

    XX

    MSB at low address

    22-23

    2

    10G Bias High Warning

    XX

    MSB at low address

    24-25

    2

    10G Bias Low Warning

    XX

    MSB at low address

    26-27

    2

    10G TX Power High Alarm

    +7dBm

    MSB at low address

    28-29

    2

    10G TX Power Low Alarm

    +1dBm

    MSB at low address

    30-31

    2

    10G TX Power High Warning

    +6dBm

    MSB at low address

    32-33

    2

    10G TX Power Low Warning

    +2dBm

    MSB at low address

    34-35

    2

    RX Power high Alarm

    -6dBm

    MSB at low address

    36-37

    2

    RX Power Low Alarm

    -28.5dBm

    MSB at low address

    38-39

    2

    RX Power high Warning

    -7dBm

    MSB at low address

    40-41

    2

    RX Power Low Warning

    -27.5dBm

    MSB at low address

    42-43

    2

    Reserved



    44-45

    2

    Reserved



    46-47

    2

    Reserved



    48-49

    2

    Reserved



    50-51

    2

    Reserved



    52-53

    2

    Reserved



    54-55

    2

    Reserved



    56-57

    2

    Reserved



    58-59

    2

    Variable power control

    0x00

    Reserved

    60-69

    10

    Reserved

    XX


    70-71

    2

    Actual BER

    XX

    Actual BER Reported by the FEC to the Module

    72-75

    4

    Wavelength Set

    XXXX

    User input of Wavelength setpoint

    76-79

    4

    FEC control

    XXXX

    FEC control register

    80-87

    8

    Alarm and Warning Flag

    XXXXXXXX

    Latched Alarm and Warning Falg(See  Alarm/Warning Falg table)

    88-95

    8

    Masking Alarm and Warning Falg

    XXXXXXXX

    Alarm and Warning Falg Masking register(See Masking Alarm/Warning Falg table)

    96-109

    14

    Diagnostic Value

    XXXXXXXXXXXXXX

    Display real-time monitoring A/D(See Diagnostic Monitor table)

    110-111

    2

    Control/status

    XX

    See General Control/Status Bits Table

    112-117

    6

    Reserved



    118

    1

    error Checking

    0x00

    Disable Packet Error Checking

    119-122

    4

    New Password Entry

    XXXX

    locations of Entry of New Optional Password

    123-126

    4

    Password Entry

    XXXX

    locations for Entry of Optional Password

    127

    1

    Table Select

    X

    Entry locations for Table Select Byte

     

    Alarm/Warning Falg table

    Addr.

    Bit

    Name of Field

    Description

    80

    7

    Temp High Alarm Flag

    Latched high Temperature alarm

    80

    6

    Temp Low Alarm Flag

    Latched Low Temperature alarm

    80

    5

    Vcc3 High Alarm Flag

    Latched high Vcc3 alarm

    80

    4

    Vcc3 Low Alarm Flag

    Latched Low Vcc3 alarm

    80

    3

    10G Bias High Alarm Flag

    Latched high 10G Bias alarm

    80

    2

    10G Bias Low Alarm Flag

    Latched Low 10G Bias alarm

    80

    1

    10G TX Power High Alarm Flag

    Latched high 10G TX Power alarm

    80

    0

    10G TX Power Low Alarm Flag

    Latched Low 10G TX Power alarm

    81

    7

    RX Power High Alarm Flag

    Latched high RX Power alarm

    81

    6

    RX Power Low Alarm Flag

    Latched Low RX Power alarm

    81

    5

    Reserved


    81

    4

    Reserved


    81

    3

    Reserved


    81

    2

    Reserved


    81

    1

    Reserved


    81

    0

    Reserved


    82

    7

    Temp High Warning Flag

    Latched high Temperature Warning

    82

    6

    Temp Low Warning Flag

    Latched Low Temperature Warning

    82

    5

    Vcc3 High Warning Flag

    Latched high Vcc3 Warning

    82

    4

    Vcc3 Low Warning Flag

    Latched Low Vcc3 Warning

    82

    3

    10G Bias High Warning Flag

    Latched high 10G Bias Warning

    82

    2

    10G Bias Low Warning Flag

    Latched Low 10G Bias Warning

    82

    1

    10G TX Power High Warning Flag

    Latched high 10G TX Power Warning

    82

    0

    10G TX Power Low Warning Flag

    Latched Low 10G TX Power Warning

    83

    7

    RX Power High Warning Flag

    Latched high RX Power Warning

    83

    6

    RX Power Low Warning Flag

    Latched Low RX Power Warning

    83

    5

    Reserved


    83

    4

    Reserved


    83

    3

    Reserved


    83

    2

    Reserved


    83

    1

    Reserved


    83

    0

    Reserved


    84

    7

    10G TX_NR Status

    Latched 10G TX_NR Status

    84

    6

    10G TX_Fault Status

    Latched 10G TX_Fault Status

    84

    5

    10G TX CDR not Locked

    Latched TX CDR Loss of Lock

    84

    4

    10G RX_NR Status

    Latched 10G RX_NR Status

    84

    3

    RX_SD Status

    Latched mirror of RX_SD pin (Receiver loss
    of optical signal)

    84

    2

    10G RX CDR not Locked

    Latched RX CDR Loss of Lock

    84

    1

    MOD_NR Status

    Latched MOD_NR status

    84

    0

    Reset Complete

    Latched Reset Complete Flag

    85

    7

    APD Supply Fault

    Latched APD Supply Fault

    85

    6

    TEC Fault

    Latched TEC Fault

    85

    5

    Wavelength Unlocked

    Latched Wavelength Unlocked Condition

    85

    4-0

    Reserved


    86

    7

    VCC5 High Alarm

    Latched VCC5 High Alarm Flag

    86

    6

    VCC5 Low Alarm

    Latched VCC5 Low Alarm Flag

    86

    5

    Vcc3 High Alarm Flag

    Latched Vcc3 high alarm Flag

    86

    4

    Vcc3 Low Alarm Flag

    Latched Vcc3 Low alarm Flag

    86

    3

    VCC2 High Alarm

    Latched Vcc2 high alarm Flag

    86

    2

    Vcc2 Low Alarm Flag

    Latched Vcc2 Low alarm Flag

    86

    1

    Vee5 High Alarm

    Latched Vee5 High Alarm Flag

    86

    0

    Vee5 Low Alarm

    Latched Vee5 Low Alarm Flag

    87

    7

    VCC5 High Warning

    Latched VCC5 High Warning Flag

    87

    6

    VCC5 Low Warning

    Latched VCC5 Low Warning Flag

    87

    5

    Vcc3 High Warning Flag

    Latched Vcc3 high Warning Flag

    87

    4

    Vcc3 Low Warning Flag

    Latched Vcc3 Low Warning Flag

    87

    3

    VCC2 High Warning

    Latched Vcc2 high Warning Flag

    87

    2

    Vcc2 Low Warning Flag

    Latched Vcc2 Low Warning Flag

    87

    1

    Vee5 High Warning

    Latched Vee5 High Warning Flag

    87

    0

    Vee5 Low Warning

    Latched Vee5 Low Warning Flag

    Masking Alarm/Warning Falg table

    Addr.

    Bit

    Name of Field

    Description

    88

    7

    Temp High Alarm Flag

    Masking bit for high Temperature alarm

    88

    6

    Temp Low Alarm Flag

    Masking bit for Low Temperature alarm

    88

    5

    Vcc3 High Alarm Flag

    Masking bit for high Vcc3 alarm

    88

    4

    Vcc3 Low Alarm Flag

    Masking bit for Low Vcc3 alarm

    88

    3

    10G Bias High Alarm Flag

    Masking bit for high 10G Bias alarm

    88

    2

    10G Bias Low Alarm Flag

    Masking bit for Low 10G Bias alarm

    88

    1

    10G TX Power High Alarm Flag

    Masking bit for high 10G TX Power alarm

    88

    0

    10G TX Power Low Alarm Flag

    Masking bit for Low 10G TX Power alarm

    89

    7

    RX Power High Alarm Flag

    Masking bit for high RX Power alarm

    89

    6

    RX Power Low Alarm Flag

    Masking bit for Low RX Power alarm

    89

    5

    Reserved


    89

    4

    Reserved


    89

    3

    Reserved


    89

    2

    Reserved


    89

    1

    Reserved


    89

    0

    Reserved


    90

    7

    Temp High Warning Flag

    Masking bit for high Temperature Warning

    90

    6

    Temp Low Warning Flag

    Masking bit for Low Temperature Warning

    90

    5

    Vcc3 High Warning Flag

    Masking bit for high Vcc3 Warning

    90

    4

    Vcc3 Low Warning Flag

    Masking bit for Low Vcc3 Warning

    90

    3

    10G Bias High Warning Flag

    Masking bit for high 10G Bias Warning

    90

    2

    10G Bias Low Warning Flag

    Masking bit for Low 10G Bias Warning

    90

    1

    10G TX Power High Warning Flag

    Masking bit for high 10G TX Power Warning

    90

    0

    10G TX Power Low Warning Flag

    Masking bit for Low 10G TX Power Warning

    91

    7

    RX Power High Warning Flag

    Masking bit for high RX Power Warning

    91

    6

    RX Power Low Warning Flag

    Masking bit for Low RX Power Warning

    91

    5

    Reserved


    91

    4

    Reserved


    91

    3

    Reserved


    91

    2

    Reserved


    91

    1

    Reserved


    91

    0

    Reserved


    92

    7

    10G TX_NR Status

    Masking bit for 10G TX_NR Status

    92

    6

    10G TX_Fault Status

    Masking bit for 10G TX_Fault Status

    92

    5

    10G TX CDR not Locked

    Masking bit for TX CDR Loss of Lock

    92

    4

    10G RX_NR Status

    Masking bit for 10G RX_NR Status

    92

    3

    RX_SD Status

    Masking bit for mirror of RX_SD pin (Receiver loss
    of optical signal)

    92

    2

    10G RX CDR not Locked

    Masking bit for RX CDR Loss of Lock

    92

    1

    MOD_NR Status

    Masking bit for MOD_NR status

    92

    0

    Reset Complete

    Masking bit for Reset Complete Flag

    93

    7

    APD Supply Fault

    Masking bit for APD Supply Fault

    93

    6

    TEC Fault

    Masking bit for TEC Fault

    93

    5

    Wavelength Unlocked

    Masking bit for Wavelength Unlocked Condition

    93

    4-0

    Reserved


    94

    7

    VCC5 High Alarm

    Masking bit for VCC5 High Alarm Flag

    94

    6

    VCC5 Low Alarm

    Masking bit for VCC5 Low Alarm Flag

    94

    5

    Vcc3 High Alarm Flag

    Masking bit for Vcc3 high alarm Flag

    94

    4

    Vcc3 Low Alarm Flag

    Masking bit for Vcc3 Low alarm Flag

    94

    3

    VCC2 High Alarm

    Masking bit for Vcc2 high alarm Flag

    94

    2

    Vcc2 Low Alarm Flag

    Masking bit for Vcc2 Low alarm Flag

    94

    1

    Vee5 High Alarm

    Masking bit for Vee5 High Alarm Flag

    94

    0

    Vee5 Low Alarm

    Masking bit for Vee5 Low Alarm Flag

    95

    7

    VCC5 High Warning

    Masking bit for VCC5 High Warning Flag

    95

    6

    VCC5 Low Warning

    Masking bit for VCC5 Low Warning Flag

    95

    5

    Vcc3 High Warning Flag

    Masking bit for Vcc3 high Warning Flag

    95

    4

    Vcc3 Low Warning Flag

    Masking bit for Vcc3 Low Warning Flag

    95

    3

    VCC2 High Warning

    Masking bit for Vcc2 high Warning Flag

    95

    2

    Vcc2 Low Warning Flag

    Masking bit for Vcc2 Low Warning Flag

    95

    1

    Vee5 High Warning

    Masking bit for Vee5 High Warning Flag

    95

    0

    Vee5 Low Warning

    Masking bit for Vee5 Low Warning Flag


    Diagnostic Monitor table

    Addr.

    Field Size

    Name of Field

    Description

    (Bytes)

    96-97

    2

    Measured Temperature

    Yield a 16-bit A/D value, MSB at low address

    98-99

    2

    Measured Vcc3

    Yield a 16-bit A/D value, MSB at low address

    100-101

    2

    Measured 10G TX Bias

    Yield a 16-bit A/D value, MSB at low address

    102-103

    2

    Measured 10G TX Power

    Yield a 16-bit A/D value, MSB at low address

    104-105

    2

    Measured RX Power

    Yield a 16-bit A/D value, MSB at low address

    106-107

    2

    Reserved


    108-109

    2

    Reserved



    External calibration constant setting and reservation functions

    Table 00h

    Addr.

    Field Size

    Name of Field

    Description

    (Bytes)

    128-131

    4

    RX Power Calibration Data4

    Single precision floating-point numbers (various values at each device)

    132-135

    4

    RX Power Calibration Data3

    136-139

    4

    RX Power Calibration Data2

    140-143

    4

    RX Power Calibration Data1

    144-147

    4

    RX Power Calibration Data0

    148-255

    108

    Reserved



    General Control/Status Bits Table

    Addr.

    Bit

    Name of Field

    Description

    110

    7

    10G TX Disable State

    Digital state of the 10G TX Disable Input Pin. Updated within 100msec of change on pin

    110

    6

    Soft 10G TX Disable

    Optional read/write bit that allows software disable of laser. Writing '1' disables laser. Turn on/off time is 100 msec max from acknowledgement of serial byte transmission. This bit is “OR”d with the hard TX_DISABLE pin value. Note, per SFP MSA TX_DISABLE pin is default enabled unless pulled low by hardware. If Soft 10G TX Disable is not implemented, the transceiver ignores the value of this bit. Default power up value is 0

    110

    5

    MOD_NR State

    Digital state of the MOD_NR Pin. Updated within 100msec of change on pin

    110

    4

    P_Down State

    Digital state of the P_Down Pin. Updated within 100msec of change on pin

    110

    3

    Soft P_Down

    Optional read/write bit that allows the module to be placed in the power

    down mode. This is identical to the P_Down hardware pin function except that it does not initiate a system reset

    110

    2

    Interrupt

    Digital state of the Interrupt output pin

    110

    1

    RX_LOS

    Indicates Optical Loss of Signal (per relevant optical link standard). Updated within 100msec of change on pin

    110

    0

    Data_Not_Ready

    Indicates transceiver has achieved power up and A/D data is ready. Bit

    remains high until data is ready to be read at which time the device sets the bit low

    111

    7

    TX_NR State

    Identifies Not Ready condition as specific to the TX path

    111

    6

    TX_Fault State

    Identifies Laser fault condition (Generated by laser safety system)

    111

    5

    TX_CDR not Locked

    Identifies Loss of Lock in TX path CDR

    111

    4

    RX_NR State

    Identifies Not Ready condition as specific to the TX path

    111

    3

    RX_CDR not Locked

    Identifies Loss of Lock in RX path CDR

    111

    2

    Reserved


    111

    1

    Reserved


    111

    0

    Reserved



    Serial ID: Data Fields

    Table 01h

    Addr.

    Field Size

    Name of Field

    Hex

    Description

    (Bytes)

    128  

    1

    Identifier

    06

    Type of serial transceiver

    129

    1

    Ext. Identifier

    D0

    Extended identifier of type of serial transceiver

    130

    1

    Connector

    01

    SC/UPC

    131-138

    8

    Transceiver

    XXXXXXXX


    139

    1

    Encoding

    10

    NRZ

    140

    1

    BR-Min

    63

    9.95Gbit/S

    141

    1

    BR-MAX

    63

    9.95Gbit/S

    142

    1

    Length(9um,km)

    14

    20km

    143

    1

    Length (9um) 100m

    00

    Transceiver transmit distance

    144

    1

    Length (50um)10m

    00

    Transceiver transmit distance

    145

    1

    Length (62.5um) 10m

    00

    Transceiver transmit distance

    146

    1

    Length (Copper)

    00

    Not compliant

    147

    1

    Device Technology

    F6

    Top 4Bits for Transmitter Technology “F” means “Reserved”; Low 4 Bits “6” means cooled transmitter and APD detector

    148-163

    16

    Vendor name

    48 47 20 47 45 4E 55 49 4E 45 20 20 20 20 20 20

    “HG GENUINE” (ASCII)

    164

    1

    CDR Support

    00

    Without CDR

    165-167

    3

    Vendor OU

    00 00 00


    168-183

    16

    Vendor PN

    50 4C 47 58 31 2D 30 31 41 20 20 20  20 20 20 20

    “PLGX1-01A” (ASCII)

    184-185

    2

    Vendor rev

    00 00


    186-187

    2

    Wavelength

    7B 34

    1577nm

    188-189

    2

    Wavelength Tolerance

    03 E8

    5nm

    190

    1

    Max Case Temp

    4B

    75

    191

    1

    CC_BASE

    XX

    Check code for Base ID Fields

    (addresses 128-190)

    192-195

    4

    Power Supply

    C8 00 8A 00

    4W,5V400mA),3.3V1A

    196-211

    16

    Vendor SN

    4D 41 30 39 30 31 30 30 33 30 30 31 33 20 20 20

    Serial Number of transceiver(ASCII).

    For example “MA09010030013”

    212-219

    8

    Date code

    31 35 30 37 32 30 20 20

    Manufactory date code.

    For example“150720”

    220

    1

    Diagnostic Monitoring Type

    08

    No BER Support, Average Power

    221

    1

    Enhanced Options

    40

    soft TX_Disable implemented

    222

    1

    Aux Monitorin

    00


    223

    1

    CC_EXT

    XX

    Check code for the Extended ID Fields (addresses 192 to 222)

    224-255


    Reserved



     

    Digital Diagnostic Monitoring Accuracy

    Addr

    Parameter

    Range

    Unit

    Accuracy

    96-97

    Temperature

    -40 to 85

    ±3

    98-99

    Supply Voltage3.3V

    3.0V to 3.6V

    V

    ±3%

    100-101

    Tx Bias Current

    0 mA to 262mA

    mA

    ±10%

    102-103

    Tx Optical Power

    2dBm to 6dBm

    dB

    ±3

    104-105

    Rx Optical Power

    -27.5dBm to -7dBm

    dB

    ±3

     

    Reset Timing Characteristics

    图片4.jpg

     

    PARAMETER

    SYMBOL

    MIN

    TYP

    MAX

    UNITS

    SD Assert Time

    Tsda1

    0

    -

    5

    ns

    SD Assert Time

    Tsda2

    0

    -

    5

    ns

    SD DeAssert Time

    Tsdd

    0

    -

    12.8

    ns

    Reset Width

    Trw

    25.6

    -

    -

    ns

    Data recovery time

    Trec

    -

    -

    25.6

    ns

    Reset To ONU Optical Time

    Trto

    0

    -

    250

    us

    Reset Guard Time

    Trg

    0

    -

    250

    us

    Reset Delay Time during Ranging

    Trdr

    0

    -

    -

    ns

    Reset Delay Time during Operating

    Trdo

    0

    -

    -

    ns

     

     

    Timing Characteristics for Digital RSSI

    图片5.jpg 

     

    PARAMETER

    SYMBOL

    MIN

    TYP

    MAX

    UNITS

    Packet Length

    -

    300

    -

    -

    ns

    Trigger delay

    Td

    25

    -

    -

    ns

    RSSI Trigger and Sample Time

    Tw

    500

    -

    -

    ns

    Internal delay

    Ts

    500

    -

    -

    us

     

    Ordering Information

    Part No.

    Specification

    Pack

    Rate

    Tx

    Pout

    Rx

    S

    Top

    Reach

    Others

    PLGX1-01A

    XFP

    2.5Gb/s U

    10.3125Gb/s D

    1577nm DFB EML

    +2-+6dBm

    APD

      <-30.5dBm

    @2.5G

    0-70

    20km

    DDM

    /ROHS


    Contact Information

    Wuhan Huagong Genuine Optics Technology Co., Ltd

    Address: Science & Technology Region of HUST, Donghu High-Tech Zone

    Wuhan, Hubei Province, 430223, China

    Tel: +86-27-87180102  

    Fax: +86-27-87180220   

    Email: market@mjbxgmy.com

    Website: http://www.mjbxgmy.com


    Statement

    HG Genuine possesses the authority for ultimate explanation of all information contained in this document, which is subject to change without prior notice. All the information was obtained in specific environments; and HG Genuine will not be responsible for verifying the products performance in customers’ operating environments, neither liable for the performance of users' products. All information contained is only for the users' reference and shall not be considered as warranted characteristics. HG Genuine will not be liable for damages arising directly or indirectly from any use of the information contained in this document.

     

    Publishing Date: 2016-1-7

     

    Copyright Ó HG Genuine

    All Right Reserved


    快盈